日本歐姆龍進口圓柱形接近傳感器of sensing distance Target Ferrous metal(The sensing distance decreases with non-ferrous metal.) Standard target (mild steel ST37) 8×8×1 mm 12×12×1 mm Power supply voltage (opera
日本歐姆龍進口圓柱形接近傳感器
• Full range of standard sizes (M8, M12, M18 and M30; both long and short barrels)
Pre-wired models (Standard length: 2 m) -M1 models:
Power source circuit reverse polarity protection,
Surge suppressor,
Please consult your OMRON representative if you have any questions or comments.
Sensing distance 2 mm ± 10% 4 mm ± 10% 4 mm ± 10% 8 mm ± 10%
Setting distance 0 to 1.6 mm 0 to 3.2 mm 0 to 3.2 mm 0 to 6.4 mm Differential travel 10% max.
of sensing distance Target Ferrous metal
(The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37) 8×8×1 mm 12×12×1 mm
Power supply voltage (operating voltage range) 12 to 24 VDC.
Ripple (p-p): 10% max. (10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type -B models: PNP open collector -C models:
• Modular construction simplifies customization.
<READ AND UNDERSTAND THIS CATALOG> Please read
of sensing distance at 23°C within temperature range of −40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95% Voltage influence ±1% max.
of sensing distance in rated voltage range ±15% Insulation resistance 50 MΩ min.
(at 500 VDC) between current carry parts and case Dielectric strength 1,000 VAC at 50/60 Hz
for 1 min between current carry parts and case Vibration resistance 10 to 55 Hz,
(under load current of 200 mA with cable length of 2 m) Indicator Operation indicator
1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 500 m/s2,
10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y
and Z directions Standard and listings (See note 3.) IEC60529: IP67,
日本歐姆龍進口圓柱形接近傳感器
Degree of protection EN60947-5-2: EMC Connection method -WP models:
NPN open collector Control output Load current
(See note 2.) 200 mA max. (32 VDC max.) Residual voltage 2 V max.
Short-circuit protection Ambient air temperature Operating:
−40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence (See note 2.) ±10% max. of sensing distance at 23°C
within temperature range of −25°C to 70°C ±15% max.
12×12×1 mm 24×24×1 mm Response frequency (See note 1.)
1,500 Hz 1,000 Hz 1,000 Hz 800 Hz
Safe Mounting with Greater Sensing Distance
• Ensures a sensing distance approximay 1.5 to 2 times larger
than that of any conventional OMRON Sensor.
• Problems such as the collision of workpieces are eliminated.
M12 4-pin connector models -M5 models:
M8 3-pin connector models Weight (packaged) Pre-wired model Approx.
65 g Approx. 85 g M12 connector model M12 connector models: Approx. 20 g M8 connector models: Approx.
15 g Approx. 35 g Material Case Stainless steel or brass-nickel
plated Brass-nickel plated Sensing surface PBT Cable PVC Clamping nut Brass-nickel plated
and understand this catalog before purchasing the products.
(Yellow LED) Operation mode (with sensing object approaching) -B1/-C1 models:
NO -B2/-C2 models: NC For details, refer to the timing charts.
Protection circuit Power source circuit reverse polarity protection,
Surge suppressor, Short-circuit protection Output reverse polarity protection,